Kategorie Fehler, Sicherheit & Diagnose
Spindelalarm
Alarm bei Störung des Spindelsystems.
Definition
Alarm bei Störung des Spindelsystems.
Die Definition im Frontmatter dient als verbindliche Bedeutung für Rüsten, Bearbeitung und Prüfung.
Formel / Regel
- Spindle alarms are usually judged by load, temperature, lubrication, inverter, or orientation state.
- Do not keep restarting the spindle until the thermal and lubrication condition is confirmed.
Typischer Bereich
- Trend spindle load, warm-up time, and lubrication status before the alarm becomes frequent.
- A cold-start alarm and a hot-running alarm usually point to different root causes.
Praxisbeispiele
- Check spindle chiller, lubrication, and orientation state when alarms appear after warm-up.
- Compare tool balance and holder condition when the alarm only appears at high RPM.
Häufige Fehler / Fehlersuche
- If the alarm appears after tool change, inspect holder balance, drawbar force, and taper cleanliness.
- If the spindle trips only under cutting load, compare commanded power with machine capability and chip evacuation.